Heat Transfer Lab Equipment
Material Testing
Tender Supply
Africa Exports
Engineering Lab
Students can recite Fourier's law and the second law of thermodynamics long before they have seen heat flow through a wall or measured a coefficient of performance. A thermal lab closes that gap, but only if each rig is chosen for what it teaches. Colleges that buy rigs from a catalogue page, rather than from the syllabus, often end up with three conduction rigs and no radiation one.
Naugra Lab Equipments manufactures and supplies heat transfer and thermodynamics teaching equipment from Ambala Cantt, Haryana, India. We supply engineering colleges, polytechnics, project contractors and distributors across Africa.
| Mode | Law or idea | What students measure | Rig |
|---|---|---|---|
| Conduction | Fourier's law | Thermal conductivity of a metal | Metal bar conductivity apparatus |
| Conduction | Resistances in series | Overall resistance of layered walls | Composite Wall Apparatus |
| Conduction | Insulation | Conductivity of an insulating material | Insulating powder apparatus, Lagged Pipe Apparatus |
| Convection | Newton's law of cooling, natural convection | Heat transfer coefficient from a heated surface | Natural Convection Apparatus |
| Convection | Forced convection in a tube | Coefficient against flow rate | Forced Convection Apparatus |
| Conduction and convection | Extended surfaces | Temperature along a fin; fin efficiency | Pin-Fin Apparatus |
| Radiation | Stefan-Boltzmann law | Stefan-Boltzmann constant; emissivity | Stefan Boltzmann Apparatus |
| Phase change | Boiling | Critical heat flux | Critical Heat Flux Apparatus, heat pipe demonstration |
| Combined | Heat exchangers | Effectiveness; parallel and counter flow | Parallel and counter-flow heat exchanger |
See heat and mass transfer lab equipment.
| Law | Idea students test | Rig |
|---|---|---|
| Zeroth law | Temperature and thermal equilibrium; thermometer calibration | Thermocouple and RTD sets with a water bath |
| First law | Energy balance: heat in, work out | Calorimeters such as the Bomb Calorimeter and Junkers Gas Calorimeter; engine test rigs |
| Second law | Heat engines and heat pumps; coefficient of performance | Mechanical Heat Pump, refrigeration trainer |
| Gas laws and processes | Pressure, volume and temperature of gases | Boyle's and Charles's law apparatus, air compressor test rig |
See fundamentals of thermodynamics and applied thermodynamics. Our post on refrigeration test rigs covers the refrigeration rig in detail.
A college on a tight budget can cover the core syllabus with six rigs: metal bar conductivity, composite wall, natural or forced convection, pin fin, Stefan-Boltzmann, and a parallel and counter-flow heat exchanger. Add a calorimeter and a heat pump or refrigeration rig for thermodynamics. That set gives every student group at least one reading for each mode of heat transfer and the first and second laws.
Thermal experiments are slow. Most rigs need 30 to 60 minutes to reach steady state, so plan practical sessions of at least two hours, or switch rigs on before the class arrives. Draughts and direct sun change results, so place rigs away from doors and windows. Check thermocouples against a reference thermometer each term; a sensor that reads two degrees high ruins a conductivity result.
Manual rigs with digital temperature indicators teach students to watch a system settle and to record readings by hand, which is a useful skill. Rigs with data logging show the approach to steady state as a curve and save class time. Many colleges buy manual rigs for first-year work and one or two logged rigs for projects. If you choose logging, ask for the software, licence and a computer connection in the same quotation.
Colleges: write the tender as the table above: law or mode, quantity measured, rig. It stops duplicate rigs and gaps.
Contractors: ask for a commissioning visit that runs one experiment per rig to steady state with the department's staff.
Distributors: keep spare heaters, thermocouples and indicators for the rigs you supply. See OEM and contract manufacturing, Heat Transfer Lab Equipment, chemical engineering lab equipment and STEM lab equipment list for engineering colleges.
Conduction through solids, convection by moving fluids, and radiation by electromagnetic waves. Most real problems combine them.
A metal bar conductivity apparatus for metals, and a composite wall or insulating powder apparatus for layered and insulating materials.
With a heat pump or refrigeration rig, by measuring the coefficient of performance and comparing it with the ideal value.
Most rigs need 30 to 60 minutes to reach steady state. Plan sessions of at least two hours, or start the rigs early.
Metal bar conductivity, composite wall, convection, pin fin, Stefan-Boltzmann and a heat exchanger, plus a calorimeter and a heat pump for thermodynamics.
Send the syllabus, class size and the power and water supply in the lab. Write to sales@naugralabequipments.com or send the details through our contact page.
Talk to our specialists about your laboratory setup or bulk-tender requirements.